Sensor
RFID corrosion environment sensor | |
Size | 90×50×15 mm |
Weight | 175 g |
Material | Ceramic |
Reader/writer
Standard type | |
Transmission Trequency | 13.56 MHz |
Standard | Cirtified conformant with technical standard |
External Dimensions | 125(D) × 125(W) × 30(H) mm (including antenna) |
Weight | 220 g |
Drive Power | USB Bus Power (DC5V, Max 150 mA) |
Options
Extension cable | For the sensor | For the RFID tag | |
Cable diameter:5 mm | Thickness:10,15 mm | Thickness:10 mm | |
Length:1,2,4,6,9,14 m |
Software
Operating environment OS: Windows Vista, Windows 7, Windows 8, Windows 8.1 and Windows 10 Memory: 1GB or greater HDD: 200MB or greater Other: USB port or LAN port connection is possible * Windows Vista, Windows 7, Windows 8, Windows 8.1 and Windows 10 are trademarks or registered trademarks of Microsoft Corporation in the United States. |
---|
This product is certified conformant with the Japanese Radio Act.
It must be certified with local radio laws before use outside of Japan.