i-CON Spacer

MaterialHigh-strength mortar
Cover thickness (mm) 30 , 35 , 40 , 45 , 50 , 60 , 70 , 80 , 90 , 100 , 110 , 120 , 130 , 140 mm
Supported rebar diameter (mm) 10 , 13 , 16 , 19 , 22 , 25 , 29 , 32 , 35 , 38 , 41 , 51 mm
Compressive strength 70 MPa or greater
Product dimensions (mm), weight (g) Product dimensions and weight differ according to the supported cover thickness
[Example] Cover thickness: 35 mm / External dimensions: 45(H)×50(W)×25(D) mm / Weight: approx. 90 g

Specifications of embedded IC tag

  HF band UHF band
Frequency band 13.56 MHz 920 MHz
Size Dia.16×3mm 13×8×3 mm
Applicable standards ISO15693 EPC Class1 Gen2
Waterproof standards IP68 IP68
Operating temperatures -25°C to 85°C -25°C to 85°C
Memory capacity 110 byte 64 byte

Reader/writer

Wireless standardsInductive reader/writer communication equipment Wireless frequency: 13.56 MHz
Communication standardsISO/IEC15693 ISO/IEC18000-3(mode1)
External dimensions 58(W)×171(D)×45(H) mm / Glip:45(W)×29(H)
Weight (including battery pack) 232 g/255 g (including external antenna)
Data transmission method Bluetooth、USB
Driving power Lithium-ion battery

This product is certified conformant with the Japanese Radio Act.
It must be certified with local radio laws before use outside of Japan.